Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in clay — test 1

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 30266 time samples and 43 published channels. Test 1: complete test record.

30,266 data rows43 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 43 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 30,2650 missing
channel_3Tip CPTNnumber-23.745 to 3.19380 missing
channel_4Tip + Friction CPTNnumber-28.239 to 7.11640 missing
channel_5PPT CPTmPanumber-0.043006 to 0.128220 missing
channel_6LoadkNnumber-4.6345 to -0.0127160 missing
channel_7PPT 7 load frontplatekPanumber-17.702 to 262.860 missing
channel_8PPT 8 load backplatekPanumber-12.313 to 307.140 missing
channel_9Displacement 1mmnumber-2.4053 to 4.26420 missing
channel_10Displacement 2mmnumber-1.4153 to 5.00260 missing
channel_11Displacement 3mmnumber-3.8011 to 3.36710 missing
channel_12Displacement 4mmnumber-2.3999 to 7.96750 missing
channel_13PPT 1kPanumber-17.694 to 181.140 missing
channel_14PPT 2kPanumber-11.807 to 140.660 missing
channel_15PPT 3kPanumber-6.4322 to 84.6350 missing
channel_16PPT 4kPanumber8.7066 to 47.8380 missing
channel_17PPT 5kPanumber-2.7835 to 12.6830 missing
channel_18PPT 6kPanumber-2.0644 to -0.45310 missing
channel_19PPT 9kPanumber-63.04 to 144.920 missing
channel_20PPT 10kPanumber-18.177 to 262.850 missing
channel_21PPT 11kPanumber-46.32 to 156.960 missing
channel_22GDD 1kPanumber55.439 to 208.550 missing
channel_23GDD 2kPanumber26.55 to 195.940 missing
channel_24GDD 3kPanumber31.603 to 191.940 missing
channel_25GDD 4kPanumber-273.96 to -35.540 missing
channel_26GDD 5kPanumber-215.09 to 7.22170 missing
channel_27GDD 6kPanumber-287.7 to 15.7930 missing
channel_28GDD 7kPanumber-384.81 to 25.8470 missing
channel_29GDD 8kPanumber-372.03 to 17.1770 missing
channel_30GDD 9kPanumber-401.66 to 26.7740 missing
channel_31GDD 10kPanumber-318.55 to 16.0250 missing
channel_32GDD 11kPanumber-208.1 to 9.33290 missing
channel_33GDD 12kPanumber-189.59 to 19.7610 missing
channel_34GDD 13kPanumber-208.77 to 0.14960 missing
channel_35GDD 14kPanumber-216.6 to 1.16520 missing
channel_36GDD 15kPanumber-223.27 to -3.09750 missing
channel_37GDD 16kPanumber-193.64 to 13.2870 missing
channel_38G-levelgnumber0.88428 to 99.8150 missing
channel_39Total unbalance (on- & off axis)kNnumber-0.001975 to 7.75320 missing
channel_40TimeStamp - New sample rate—text0 missing
channel_41Time 2 - fast sample ratesnumber0 to 30,2650 missing
channel_42CPT plungermmnumber-53.058 to 55.1010 missing
channel_43Load plungermmnumber-70.068 to 50.880 missing

Test context & data notes

Physical test number
1
Soil
clay
Phase
complete test record
Original archive member
Part A - measurement data/Test 1 - clay_Sampling_Rate_1.0Hz_2_StopTime_20211103-171831000032_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-1.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 9788f82dcae793b9cd6801324bac2a61c1873e66b3b5cf65ee72511c32bae52b
CSV25.27 MB · 25,274,969 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22