Foundation load tests
Deltares centrifuge — plate loading in clay — test 1
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation Design · Evidence library
Download compact measurements, examine their columns and units, and explore the data before using them.
Each record identifies a test, profile or compact dataset. Collection names keep related records together; they are not separate research studies. 15 source collections are represented.
Eight centrifuge plate-loading tests in clay and peat, provided in nine original instrument files. Videos and laser scans remain with the publisher.
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
Foundation load tests
Deltares centrifuge calibration chamber
TimeStamp - New sample rate · Time 2 - default sample rate (s) · Tip CPT (N) · Tip + Friction CPT (N) …
| Data record | Collection / type | Rows / columns | Region | Download |
|---|---|---|---|---|
| Deltares centrifuge — plate loading in clay — test 1Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 30,266 rows43 columns | Netherlands | CSV · 25.3 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in peat — test 2Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 8,786 rows44 columns | Netherlands | CSV · 7.4 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in clay — test 3, spin-up and consolidationFoundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 25,193 rows46 columns | Netherlands | CSV · 13.9 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in clay — test 3, loading phaseFoundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 3,408 rows46 columns | Netherlands | CSV · 3.0 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in peat — test 4Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 17,788 rows46 columns | Netherlands | CSV · 15.4 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in peat — test 5Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 18,678 rows46 columns | Netherlands | CSV · 16.2 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in clay — test 6Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 32,675 rows46 columns | Netherlands | CSV · 28.4 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in peat — test 7Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 18,319 rows46 columns | Netherlands | CSV · 16.1 MBCC BY 4.0 |
| Deltares centrifuge — plate loading in clay — test 8Foundation load tests | Deltares centrifuge calibration chamberPhysical model tests | 33,288 rows46 columns | Netherlands | CSV · 29.0 MBCC BY 4.0 |
Check the measured variables, units, preview and data notes. Plots use the actual records available in the preview.
Keep the collection citation, original file and reuse terms with any derived table or research model.
For machine learning, group related sites and specimens when creating training and evaluation sets.