Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in peat — test 4

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 17788 time samples and 46 published channels. Test 4: complete test record.

17,788 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 17,7870 missing
channel_3Tip CPTNnumber-11.836 to 317.80 missing
channel_4Tip + Friction CPTNnumber-30.041 to 447.830 missing
channel_5PPT CPTmPanumber-0.0097236 to 0.182260 missing
channel_6LoadkNnumber-1.5933 to 3.13090 missing
channel_7PPT 7 load frontplatekPanumber-1,000,000 to -1,000,0000 missing
channel_8PPT 8 load backplatekPanumber-1,000,000 to -1,000,0000 missing
channel_9Displacement 1mmnumber2.1719 to 2.92590 missing
channel_10Displacement 2mmnumber3.1447 to 4.05540 missing
channel_11Displacement 3mmnumber-1,000,000 to -1,000,0000 missing
channel_12Displacement 4mmnumber3.8811 to 5.19840 missing
channel_13PPT 1kPanumber0.41142 to 230.720 missing
channel_14PPT 2kPanumber7.0817 to 207.220 missing
channel_15PPT 3kPanumber4.0138 to 168.980 missing
channel_16PPT 4kPanumber10.36 to 145.70 missing
channel_17PPT 5kPanumber0.67838 to 100.730 missing
channel_18PPT 6kPanumber-0.84352 to 67.1480 missing
channel_19PPT 9kPanumber16.598 to 249.850 missing
channel_20PPT 10kPanumber2.4664 to 235.510 missing
channel_21PPT 11kPanumber-15.273 to 610.660 missing
channel_22Waterheight reservoirkPanumber1.42 to 126.080 missing
channel_23PPT 12 load frontplatekPanumber-32.959 to 532.980 missing
channel_24PPT13 load backplatekPanumber-2.488 to 130.840 missing
channel_25GDD 1kPanumber81.88 to 282.490 missing
channel_26GDD 2kPanumber33.442 to 237.740 missing
channel_27GDD 3kPanumber38.685 to 274.890 missing
channel_28GDD 4kPanumber-493.57 to -95.850 missing
channel_29GDD 5kPanumber-280.53 to -28.3330 missing
channel_30GDD 6kPanumber-266.19 to -7.44250 missing
channel_31GDD 7kPanumber-258.52 to 1.88210 missing
channel_32GDD 8kPanumber-275.46 to -21.1220 missing
channel_33GDD 9kPanumber-249.16 to 11.4140 missing
channel_34GDD 10kPanumber-299.58 to -21.3380 missing
channel_35GDD 11kPanumber-797.87 to 8.02780 missing
channel_36GDD 12kPanumber-706.85 to -14.9790 missing
channel_37GDD 13kPanumber-896.26 to -12.5040 missing
channel_38GDD 14kPanumber-334.85 to -21.5710 missing
channel_39GDD 15kPanumber-280.99 to -18.0790 missing
channel_40GDD 16kPanumber-222.84 to 4.99340 missing
channel_41G-levelgnumber0.87807 to 99.8540 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.0016146 to 6.35860 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 17,7870 missing
channel_45CPT plungermmnumber-53.074 to 150.150 missing
channel_46Load plungermmnumber-41.08 to 185.450 missing

Test context & data notes

Physical test number
4
Soil
peat
Phase
complete test record
Original archive member
Part A - measurement data/Test 4 - peat_Sampling_Rate_1.0Hz_2_StopTime_20211123-144600000019_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-4.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 246151f5db7732512ed5d43a60e85efd4b371f2fc05c9deec47f84d58876b994
CSV15.38 MB · 15,375,754 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22