Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in peat — test 2

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 8786 time samples and 44 published channels. Test 2: complete test record.

8,786 data rows44 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 44 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 8,7850 missing
channel_3Tip CPTNnumber-3.2005 to 360.440 missing
channel_4Tip + Friction CPTNnumber-18.694 to 509.030 missing
channel_5PPT CPTmPanumber-0.012617 to 0.207310 missing
channel_6LoadkNnumber-4.1436 to 18.1620 missing
channel_7PPT 7 load frontplatekPanumber-61.975 to 756.930 missing
channel_8PPT 8 load backplatekPanumber-29.391 to 551.630 missing
channel_9Displacement 1mmnumber0.40562 to 31.0260 missing
channel_10Displacement 2mmnumber0.58164 to 32.6930 missing
channel_11Displacement 3mmnumber-0.20822 to 5.26290 missing
channel_12Displacement 4mmnumber-2.5629 to 9.37730 missing
channel_13PPT 1kPanumber2.6066 to 251.430 missing
channel_14PPT 2kPanumber5.0226 to 227.880 missing
channel_15PPT 3kPanumber2.697 to 190.830 missing
channel_16PPT 4kPanumber5.0103 to 153.240 missing
channel_17PPT 5kPanumber-0.00085079 to 107.170 missing
channel_18PPT 6kPanumber0.51368 to 76.5240 missing
channel_19PPT 9kPanumber12.554 to 274.340 missing
channel_20PPT 10kPanumber-17.074 to 506.830 missing
channel_21PPT 11kPanumber5.876 to 413.110 missing
channel_22Waterheight reservoirkPanumber1.2921 to 117.130 missing
channel_23GDD 1kPanumber60.005 to 277.130 missing
channel_24GDD 2kPanumber32.159 to 262.30 missing
channel_25GDD 3kPanumber45.426 to 291.030 missing
channel_26GDD 4kPanumber-434.69 to -61.740 missing
channel_27GDD 5kPanumber-381.33 to -28.2510 missing
channel_28GDD 6kPanumber-536.11 to -19.0370 missing
channel_29GDD 7kPanumber-1,392.9 to 12.7260 missing
channel_30GDD 8kPanumber-1,113 to -22.1190 missing
channel_31GDD 9kPanumber-1,628.2 to 5.09660 missing
channel_32GDD 10kPanumber-843.65 to -34.9490 missing
channel_33GDD 11kPanumber-437.85 to 8.82780 missing
channel_34GDD 12kPanumber-399.98 to -2.9910 missing
channel_35GDD 13kPanumber-459.93 to -25.6930 missing
channel_36GDD 14kPanumber-338.31 to -7.07850 missing
channel_37GDD 15kPanumber-299.73 to -4.50280 missing
channel_38GDD 16kPanumber-339.34 to -1.25920 missing
channel_39G-levelgnumber0.8508 to 99.8080 missing
channel_40Total unbalance (on- & off axis)kNnumber-0.0017299 to 6.91810 missing
channel_41TimeStamp - New sample rate—text0 missing
channel_42Time 2 - fast sample ratesnumber0 to 8,7850 missing
channel_43CPT plungermmnumber-53.051 to 146.210 missing
channel_44Load plungermmnumber-48.58 to 132.270 missing

Test context & data notes

Physical test number
2
Soil
peat
Phase
complete test record
Original archive member
Part A - measurement data/Test 2 - peat_Sampling_Rate_1.0Hz_2_StopTime_20211110-115252999968_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-2.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 62f051c444f2b45925a4cf9839697b6e884281e965ae39bc2a581122e68a133b
CSV7.40 MB · 7,404,848 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22