Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in clay — test 3, loading phase

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 3408 time samples and 46 published channels. Test 3: loading phase.

3,408 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 3,4070 missing
channel_3Tip CPTNnumber-11.77 to 11.6230 missing
channel_4Tip + Friction CPTNnumber-23.576 to 17.5620 missing
channel_5PPT CPTmPanumber-0.036233 to 0.140090 missing
channel_6LoadkNnumber-1.5426 to 0.198870 missing
channel_7PPT 7 load frontplatekPanumber-1,000,000 to -1,000,0000 missing
channel_8PPT 8 load backplatekPanumber-1,000,000 to -1,000,0000 missing
channel_9Displacement 1mmnumber-9.3062 to -8.34180 missing
channel_10Displacement 2mmnumber-8.9741 to -8.42840 missing
channel_11Displacement 3mmnumber-1,000,000 to -1,000,0000 missing
channel_12Displacement 4mmnumber-5.3821 to -2.63260 missing
channel_13PPT 1kPanumber-43.273 to 2370 missing
channel_14PPT 2kPanumber-8.2551 to 151.980 missing
channel_15PPT 3kPanumber-6.0075 to 81.9360 missing
channel_16PPT 4kPanumber18.106 to 28.7480 missing
channel_17PPT 5kPanumber1.5623 to 4.02480 missing
channel_18PPT 6kPanumber2.4158 to 4.13110 missing
channel_19PPT 9kPanumber36.163 to 216.630 missing
channel_20PPT 10kPanumber-33.068 to 151.240 missing
channel_21PPT 11kPanumber-13.181 to 198.390 missing
channel_22Waterheight reservoirkPanumber1.6027 to 120.590 missing
channel_23PPT 12 load frontplatekPanumber-18.298 to 239.420 missing
channel_24PPT13 load backplatekPanumber-2.2468 to 68.7270 missing
channel_25GDD 1kPanumber52.754 to 180.820 missing
channel_26GDD 2kPanumber27.186 to 194.880 missing
channel_27GDD 3kPanumber44.792 to 213.050 missing
channel_28GDD 4kPanumber-284.59 to -41.40 missing
channel_29GDD 5kPanumber-243.62 to -35.0550 missing
channel_30GDD 6kPanumber-196.76 to -9.5130 missing
channel_31GDD 7kPanumber-171.51 to 6.37620 missing
channel_32GDD 8kPanumber-209.87 to -22.5560 missing
channel_33GDD 9kPanumber-183.89 to -2.41620 missing
channel_34GDD 10kPanumber-198.8 to 1.67950 missing
channel_35GDD 11kPanumber-223.54 to 4.02520 missing
channel_36GDD 12kPanumber-204.99 to 6.06330 missing
channel_37GDD 13kPanumber-214.79 to 0.40590 missing
channel_38GDD 14kPanumber-260.41 to 1.77850 missing
channel_39GDD 15kPanumber-217.87 to -13.9650 missing
channel_40GDD 16kPanumber-170.73 to 14.6630 missing
channel_41G-levelgnumber0.87368 to 99.8120 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.0018164 to 5.83620 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 3,4070 missing
channel_45CPT plungermmnumber-53.038 to 45.0480 missing
channel_46Load plungermmnumber-41.08 to 60.0310 missing

Test context & data notes

Physical test number
3
Soil
clay
Phase
loading phase
Original archive member
Part A - measurement data/Test 3 - clay - part 2_Sampling_Rate_1.0Hz_2_StopTime_20211116-172551999974_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-3-part-2.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 c56bef6c21d19795ac8e9a9a22acf847b156522ddc21df83c8f9eb5abc9db741
CSV2.96 MB · 2,960,294 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22