Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in clay — test 3, spin-up and consolidation

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 25193 time samples and 46 published channels. Test 3: spin-up and consolidation.

25,193 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 25,1920 missing
channel_3Tip CPTNnumber-17.981 to -3.58370 missing
channel_4Tip + Friction CPTNnumber-27.839 to 8.52530 missing
channel_5PPT CPTmPanumber-0.021048 to 0.0571360 missing
channel_6LoadkNnumber-4.6071 to 0.12490 missing
channel_7PPT 7 load frontplatekPanumber-1,000,000 to -14.9910 missing
channel_8PPT 8 load backplatekPanumber-1,000,000 to -10.620 missing
channel_9Displacement 1mmnumber-9.2944 to -2.26420 missing
channel_10Displacement 2mmnumber-8.7292 to -1.27590 missing
channel_11Displacement 3mmnumber-1,000,000 to -3.49690 missing
channel_12Displacement 4mmnumber-5.371 to -1.52070 missing
channel_13PPT 1kPanumber-6.3305 to 184.380 missing
channel_14PPT 2kPanumber-2.4991 to 143.470 missing
channel_15PPT 3kPanumber-5.1051 to 92.8480 missing
channel_16PPT 4kPanumber15.746 to 65.3730 missing
channel_17PPT 5kPanumber-0.51703 to 28.3290 missing
channel_18PPT 6kPanumber-0.76546 to 4.85560 missing
channel_19PPT 9kPanumber63.137 to 275.130 missing
channel_20PPT 10kPanumber1.5862 to 193.660 missing
channel_21PPT 11kPanumber11.567 to 203.220 missing
channel_22Waterheight reservoirkPanumber1.4689 to 130.8816 missing
channel_23PPT 12 load frontplatekPanumber2.6619 to 57.90716 missing
channel_24PPT13 load backplatekPanumber3.1903 to 59.03116 missing
channel_25GDD 1kPanumber61.534 to 224.460 missing
channel_26GDD 2kPanumber32.587 to 213.490 missing
channel_27GDD 3kPanumber35.365 to 202.420 missing
channel_28GDD 4kPanumber-291.96 to -39.670 missing
channel_29GDD 5kPanumber-269.06 to -22.1190 missing
channel_30GDD 6kPanumber-225.65 to 0.918480 missing
channel_31GDD 7kPanumber-198.07 to 11.9550 missing
channel_32GDD 8kPanumber-241.86 to -19.1350 missing
channel_33GDD 9kPanumber-209.63 to 4.34190 missing
channel_34GDD 10kPanumber-226.57 to -0.927150 missing
channel_35GDD 11kPanumber-215.01 to 4.57960 missing
channel_36GDD 12kPanumber-211.9 to 4.50810 missing
channel_37GDD 13kPanumber-212.3 to -1.35990 missing
channel_38GDD 14kPanumber-240.93 to -3.93550 missing
channel_39GDD 15kPanumber-251.41 to -16.4090 missing
channel_40GDD 16kPanumber-207.38 to 1.46620 missing
channel_41G-levelgnumber0.84878 to 99.8530 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.007655 to 7.01280 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 25,1920 missing
channel_45CPT plungermmnumber44.932 to 45.3880 missing
channel_46Load plungermmnumber59.925 to 61.5660 missing

Test context & data notes

Physical test number
3
Soil
clay
Phase
spin-up and consolidation
Original archive member
Part A - measurement data/Test 3 - clay - part 1_Sampling_Rate_1.0Hz_3_StopTime_20211116-162435000006_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-3-part-1.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 badc6d4c92abd273b76b6fcc52da209943b4c2621f4a9e8a746aaed7cf419319
CSV13.87 MB · 13,869,957 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22