Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in clay — test 6

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 32675 time samples and 46 published channels. Test 6: complete test record.

32,675 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 32,6740 missing
channel_3Tip CPTNnumber-20.736 to 1.10620 missing
channel_4Tip + Friction CPTNnumber-44.819 to -10.4490 missing
channel_5PPT CPTmPanumber-0.032406 to 0.128450 missing
channel_6LoadkNnumber-1.6281 to 0.235350 missing
channel_7PPT 7 load frontplatekPanumber-1,000,000 to -1,000,0000 missing
channel_8PPT 8 load backplatekPanumber-1,000,000 to -1,000,0000 missing
channel_9Displacement 1mmnumber6.7401 to 12.5980 missing
channel_10Displacement 2mmnumber6.6492 to 12.9630 missing
channel_11Displacement 3mmnumber-1,000,000 to -1,000,0000 missing
channel_12Displacement 4mmnumber10.481 to 16.3340 missing
channel_13PPT 1kPanumber-16.072 to 170.950 missing
channel_14PPT 2kPanumber-3.7536 to 113.810 missing
channel_15PPT 3kPanumber-4.1577 to 52.6170 missing
channel_16PPT 4kPanumber14.713 to 27.0050 missing
channel_17PPT 5kPanumber1.1097 to 2.96830 missing
channel_18PPT 6kPanumber-1.7692 to 0.51480 missing
channel_19PPT 9kPanumber22.192 to 223.620 missing
channel_20PPT 10kPanumber-30.149 to 166.370 missing
channel_21PPT 11kPanumber-0.27398 to 230.430 missing
channel_22Waterheight reservoirkPanumber0.77539 to 130.960 missing
channel_23PPT 12 load frontplatekPanumber-6.6619 to 231.510 missing
channel_24PPT13 load backplatekPanumber-5.3546 to 252.250 missing
channel_25GDD 1kPanumber58.939 to 186.230 missing
channel_26GDD 2kPanumber31.226 to 175.250 missing
channel_27GDD 3kPanumber30.192 to 166.770 missing
channel_28GDD 4kPanumber-238.36 to -19.9640 missing
channel_29GDD 5kPanumber-227.34 to -23.7330 missing
channel_30GDD 6kPanumber-175.26 to 10.1460 missing
channel_31GDD 7kPanumber-164.61 to 13.2620 missing
channel_32GDD 8kPanumber-197.25 to -16.1280 missing
channel_33GDD 9kPanumber-162.25 to 14.170 missing
channel_34GDD 10kPanumber-191.04 to 5.94790 missing
channel_35GDD 11kPanumber-292.69 to 19.1710 missing
channel_36GDD 12kPanumber-252.97 to 12.780 missing
channel_37GDD 13kPanumber-265.66 to 1.50750 missing
channel_38GDD 14kPanumber-202.89 to 3.89170 missing
channel_39GDD 15kPanumber-206.31 to -9.97270 missing
channel_40GDD 16kPanumber-161.8 to 24.7150 missing
channel_41G-levelgnumber0.87778 to 99.8530 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.0018597 to 6.65460 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 32,6740 missing
channel_45CPT plungermmnumber-53.06 to 40.0650 missing
channel_46Load plungermmnumber-41.382 to 62.3550 missing

Test context & data notes

Physical test number
6
Soil
clay
Phase
complete test record
Original archive member
Part A - measurement data/Test 6 - clay_Sampling_Rate_1.0Hz_2_StopTime_20211130-175445000028_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-6.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 473c485d6e7e15d6df2b7369e9df09cf2dc5ad658d59848c888509d4814574e2
CSV28.36 MB · 28,358,268 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22