Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in clay — test 8

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 33288 time samples and 46 published channels. Test 8: complete test record.

33,288 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 33,2870 missing
channel_3Tip CPTNnumber-37.316 to -13.7130 missing
channel_4Tip + Friction CPTNnumber-77.936 to -42.7680 missing
channel_5PPT CPTmPanumber-0.031535 to 0.128340 missing
channel_6LoadkNnumber-5.3229 to -0.640930 missing
channel_7PPT 7 load frontplatekPanumber-24.873 to 290.540 missing
channel_8PPT 8 load backplatekPanumber-26.247 to 295.850 missing
channel_9Displacement 1mmnumber-1.0082 to 3.62940 missing
channel_10Displacement 2mmnumber0.72257 to 4.77480 missing
channel_11Displacement 3mmnumber-2.0668 to 5.73220 missing
channel_12Displacement 4mmnumber-1.3095 to 9.09170 missing
channel_13PPT 1kPanumber-23.843 to 146.920 missing
channel_14PPT 2kPanumber-13.826 to 108.610 missing
channel_15PPT 3kPanumber-8.4325 to 55.3210 missing
channel_16PPT 4kPanumber11.737 to 31.5240 missing
channel_17PPT 5kPanumber2.2204 to 4.68620 missing
channel_18PPT 6kPanumber6.2072 to 10.3670 missing
channel_19PPT 9kPanumber-21 to 180.020 missing
channel_20PPT 10kPanumber-5.3384 to 310.790 missing
channel_21PPT 11kPanumber-16.263 to 180.370 missing
channel_22Waterheight reservoirkPanumber1.5378 to 130.130 missing
channel_23PPT 12 load frontplatekPanumber-1,000,000 to -1,000,0000 missing
channel_24PPT13 load backplatekPanumber-1,000,000 to -1,000,0000 missing
channel_25GDD 1kPanumber62.549 to 190.290 missing
channel_26GDD 2kPanumber31.233 to 177.150 missing
channel_27GDD 3kPanumber27.271 to 163.460 missing
channel_28GDD 4kPanumber-221.67 to -21.8120 missing
channel_29GDD 5kPanumber-227.21 to -24.5170 missing
channel_30GDD 6kPanumber-247.04 to 11.7680 missing
channel_31GDD 7kPanumber-454.22 to 20.4420 missing
channel_32GDD 8kPanumber-375.59 to -14.480 missing
channel_33GDD 9kPanumber-464.31 to 14.6580 missing
channel_34GDD 10kPanumber-300.71 to 7.19950 missing
channel_35GDD 11kPanumber-176.32 to 25.420 missing
channel_36GDD 12kPanumber-176.6 to 2.67190 missing
channel_37GDD 13kPanumber-192.45 to -3.13090 missing
channel_38GDD 14kPanumber-197.67 to 1.74980 missing
channel_39GDD 15kPanumber-199.64 to -8.87050 missing
channel_40GDD 16kPanumber-158.39 to 22.5750 missing
channel_41G-levelgnumber0.85817 to 99.8080 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.0014704 to 6.19510 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 33,2870 missing
channel_45CPT plungermmnumber-53.088 to 45.1310 missing
channel_46Load plungermmnumber-70.086 to 38.5910 missing

Test context & data notes

Physical test number
8
Soil
clay
Phase
complete test record
Original archive member
Part A - measurement data/Test 8 - clay_Sampling_Rate_1.0Hz_2_StopTime_20211207-173714000016_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-8.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 1a3c7ec8f49bd3231f3899ea7eca5bfafa8829b7ba1c887760afc4c5cc1f4be7
CSV29.04 MB · 29,041,986 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22