Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in peat — test 5

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 18678 time samples and 46 published channels. Test 5: complete test record.

18,678 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 18,6770 missing
channel_3Tip CPTNnumber-11.32 to 128.980 missing
channel_4Tip + Friction CPTNnumber-26.03 to 203.380 missing
channel_5PPT CPTmPanumber-0.013936 to 0.177630 missing
channel_6LoadkNnumber-1.5457 to 2.6390 missing
channel_7PPT 7 load frontplatekPanumber-1,000,000 to -1,000,0000 missing
channel_8PPT 8 load backplatekPanumber-1,000,000 to -1,000,0000 missing
channel_9Displacement 1mmnumber0.70915 to 1.4170 missing
channel_10Displacement 2mmnumber0.27527 to 1.6250 missing
channel_11Displacement 3mmnumber-1,000,000 to -1,000,0000 missing
channel_12Displacement 4mmnumber3.7589 to 4.70360 missing
channel_13PPT 1kPanumber-3.7428 to 232.310 missing
channel_14PPT 2kPanumber5.2112 to 215.080 missing
channel_15PPT 3kPanumber0.64151 to 173.980 missing
channel_16PPT 4kPanumber9.2686 to 131.580 missing
channel_17PPT 5kPanumber1.0345 to 88.6870 missing
channel_18PPT 6kPanumber-1.8957 to 49.080 missing
channel_19PPT 9kPanumber4.0712 to 232.640 missing
channel_20PPT 10kPanumber-0.35718 to 230.160 missing
channel_21PPT 11kPanumber-7.7582 to 409.230 missing
channel_22Waterheight reservoirkPanumber0.84041 to 124.40 missing
channel_23PPT 12 load frontplatekPanumber-20.516 to 350.220 missing
channel_24PPT13 load backplatekPanumber-15.915 to 179.290 missing
channel_25GDD 1kPanumber63.791 to 255.180 missing
channel_26GDD 2kPanumber47.738 to 244.160 missing
channel_27GDD 3kPanumber36.716 to 249.410 missing
channel_28GDD 4kPanumber-366.43 to -21.10 missing
channel_29GDD 5kPanumber-273.83 to -28.6470 missing
channel_30GDD 6kPanumber-247.84 to -0.573930 missing
channel_31GDD 7kPanumber-243.74 to 4.59310 missing
channel_32GDD 8kPanumber-259.62 to -25.6460 missing
channel_33GDD 9kPanumber-233.17 to 14.4070 missing
channel_34GDD 10kPanumber-283.26 to 1.66690 missing
channel_35GDD 11kPanumber-741.01 to 5.78680 missing
channel_36GDD 12kPanumber-655.74 to 6.30630 missing
channel_37GDD 13kPanumber-738.69 to -5.20570 missing
channel_38GDD 14kPanumber-312.44 to -3.54980 missing
channel_39GDD 15kPanumber-272.4 to -14.5140 missing
channel_40GDD 16kPanumber-205.42 to 19.0450 missing
channel_41G-levelgnumber0.82876 to 99.8510 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.0020327 to 6.79680 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 18,6770 missing
channel_45CPT plungermmnumber-53.054 to 150.130 missing
channel_46Load plungermmnumber-41.077 to 175.060 missing

Test context & data notes

Physical test number
5
Soil
peat
Phase
complete test record
Original archive member
Part A - measurement data/Test 5 - peat_Sampling_Rate_1.0Hz_2_StopTime_20211125-134951999974_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-5.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 c87e803609e0f12777e93ed19a206700fe6bf59f8ce142bb9b98ab3e7bfbafd8
CSV16.18 MB · 16,179,904 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22