Physical model tests · Physical-test measurement file

Deltares centrifuge — plate loading in peat — test 7

Deltares / TU Delft / Equinor

Original semicolon-delimited instrument record for centrifuge plate loading; 18319 time samples and 46 published channels. Test 7: complete test record.

18,319 data rows46 columnsNetherlands

Explore the data

Loading the data preview…

Columns, features & units

TimeStamp - New sample rateTime 2 - default sample rate (s)Tip CPT (N)Tip + Friction CPT (N)PPT CPT (mPa)Load (kN)PPT 7 load frontplate (kPa)PPT 8 load backplate (kPa)
View the full data dictionary · 46 columns
ColumnMeaningUnitData coverage
channel_1TimeStamp - New sample rate—text0 missing
channel_2Time 2 - default sample ratesnumber0 to 18,3180 missing
channel_3Tip CPTNnumber-14.376 to 61.2570 missing
channel_4Tip + Friction CPTNnumber-39.784 to 84.6490 missing
channel_5PPT CPTmPanumber-0.022264 to 0.177530 missing
channel_6LoadkNnumber-5.2106 to 13.5540 missing
channel_7PPT 7 load frontplatekPanumber-28.584 to 797.780 missing
channel_8PPT 8 load backplatekPanumber-33.603 to 440.280 missing
channel_9Displacement 1mmnumber-3.1951 to -1.80150 missing
channel_10Displacement 2mmnumber-0.65895 to 0.0311470 missing
channel_11Displacement 3mmnumber0.26193 to 1.19630 missing
channel_12Displacement 4mmnumber-0.80789 to 3.02350 missing
channel_13PPT 1kPanumber-0.635 to 213.330 missing
channel_14PPT 2kPanumber6.8258 to 193.520 missing
channel_15PPT 3kPanumber0.59128 to 144.970 missing
channel_16PPT 4kPanumber9.4435 to 121.720 missing
channel_17PPT 5kPanumber1.6644 to 79.9520 missing
channel_18PPT 6kPanumber-3.7552 to 42.0860 missing
channel_19PPT 9kPanumber-20.273 to 215.470 missing
channel_20PPT 10kPanumber-7.3045 to 678.460 missing
channel_21PPT 11kPanumber9.9651 to 247.30 missing
channel_22Waterheight reservoirkPanumber1.1196 to 120.10 missing
channel_23PPT 12 load frontplatekPanumber-1,000,000 to -1,000,0000 missing
channel_24PPT13 load backplatekPanumber-1,000,000 to -1,000,0000 missing
channel_25GDD 1kPanumber65.207 to 280.230 missing
channel_26GDD 2kPanumber41.577 to 269.720 missing
channel_27GDD 3kPanumber37.501 to 275.540 missing
channel_28GDD 4kPanumber-320.67 to -27.8170 missing
channel_29GDD 5kPanumber-296.6 to -26.1860 missing
channel_30GDD 6kPanumber-907.87 to 14.8510 missing
channel_31GDD 7kPanumber-1,747.4 to 14.720 missing
channel_32GDD 8kPanumber-1,254.6 to -17.4740 missing
channel_33GDD 9kPanumber-1,505.3 to 16.4060 missing
channel_34GDD 10kPanumber-575.83 to 7.08220 missing
channel_35GDD 11kPanumber-392.36 to 13.2030 missing
channel_36GDD 12kPanumber-409.21 to 4.67490 missing
channel_37GDD 13kPanumber-301.99 to -3.36540 missing
channel_38GDD 14kPanumber-372.09 to -3.13440 missing
channel_39GDD 15kPanumber-349 to -49.60 missing
channel_40GDD 16kPanumber-217.44 to 14.3070 missing
channel_41G-levelgnumber0.82573 to 99.8550 missing
channel_42Total unbalance (on- & off axis)kNnumber-0.0017876 to 6.38430 missing
channel_43TimeStamp - New sample rate—text0 missing
channel_44Time 2 - fast sample ratesnumber0 to 18,3180 missing
channel_45CPT plungermmnumber-53.054 to 150.120 missing
channel_46Load plungermmnumber-44.54 to 144.090 missing

Test context & data notes

Physical test number
7
Soil
peat
Phase
complete test record
Original archive member
Part A - measurement data/Test 7 - peat_Sampling_Rate_1.0Hz_2_StopTime_20211202-143219000003_concat.csv
Delimiter
Semicolon
Source archive MD5
md5:ea0869288b454f31c6c304264d989e04
Preview column mapping
channel_N maps to the Nth original CSV column; duplicate timestamp headers are preserved in the original file.
  • Nine measurement files belong to eight physical tests: test 3 has separate consolidation and loading files. File count is not the number of independent physical experiments.
  • The downloaded CSV is the original archive member without numeric changes. Preview channel keys only identify column positions; original headers and units remain in the data dictionary.
  • The header unit “mPa” for PPT CPT is retained literally. Consult the factual report before interpreting that channel; no capitalization or unit conversion has been inferred.
  • Measurements include spin-up and consolidation where present. Negative offsets and instrument readings are preserved; channel location and calibration require the publisher’s factual report.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
deltares-plate-test-7.csvExtracted original CSV archive member; no changes to file contents.
File checksumSHA256 7ac31d58ce925fcd6a1bfbf818f11e6b02e6055ffa0cd421f459547d5a95aaae
CSV16.06 MB · 16,059,207 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Zwanenburg, C., Witteloek, B., Martinelli, M., Alderlieste, E., and Zwaan, R. (2023). Calibration chamber for numerical tools. Zenodo. https://doi.org/10.5281/zenodo.8066899. DOI: 10.5281/zenodo.8066899.

View the primary source

Source version: Zenodo record 8066899, version 1 (2023) · retrieved 2026-11-22